Dairy Processing and Products Research Unit, US Department of Agriculture, Eastern Regional Research Center, Agricultural Research Service, Wyndmoor, PA 19038
Corresponding author: P. M. Tomasula; e-mail: ptomasula{at}errc.ars.usda.gov.
| ABSTRACT |
|---|
|
|
|---|
Tracer studies were used to determine FMP times and RTD data to establish flow characteristics. Using brine milk as tracer, the FMP time for the short holding section was 18.6 s and for the long holding section was 36 s at 72°C, compared with the nominal times of 21.5 and 52.2 s, respectively. The RTD study indicates that the short hold section was 45% back mixed and 55% plug flow for whole milk at 72°C. The long hold section was 91% plug and 9% back mixed for whole milk at 72°C. This study demonstrates that continuous laboratory and pilot-scale pasteurizers may be used to study inactivation of microorganisms only if the flow conditions in the holding tube are established for comparison with commercial HTST systems.
Key Words: pasteurization milk Foot-and-Mouth Disease Mycobacterium paratuberculosis
Abbreviation key: FMD = Foot-and-Mouth Disease, FMP = fastest moving particle, Mptb = Mycobacterium paratuberculosis, RTD = residence time distribution
| INTRODUCTION |
|---|
|
|
|---|
In the US, milk usually is pasteurized commercially using HTST pasteurization. Flow conditions must be such that all particles of milk are held in the holding tube for a minimum of 15 s at a temperature of at least 72°C, with none leaving before the prescribed holding time (PMO, 2001). The holding tube length must be such that the fastest moving particle (FMP) time of any product will not traverse the holding tube in less than the required holding time. As pointed out by Hasting et al. (2001), the FMP from a microbiological safety viewpoint must be characterized, and this particle must receive at least the minimum defined pasteurization process. In this way, experimental conditions may be related to industrial practice.
A variety of laboratory methods developed to simulate the entire HTST pasteurization process have been used to determine the effectiveness of pasteurization for elimination of Mycobacterium paratuberculosis (MPtb) in milk. Mycobacterium paratuberculosis is the causative agent of Johnes Disease in dairy cattle and may be associated with Crohns disease in humans. Experiments were carried out using the standard holder method (Grant et al., 1996), a simulated HTST method (Gao et al., 2002), and commercial HTST pilot-scale pasteurizers (Hope et al., 1997; Stabel et al., 1997). The pilot-scale pasteurizers have the advantage of simulating the come-up and cool down times of the larger commercial pasteurizers. The results from the studies were conflicting and were interpreted independent of parallel experiments to determine the FMP time for the experimental apparatus that must be known for application to commercial-scale operations. Cerf and Griffiths (2000) suggested that reliable results on the effectiveness of pasteurization to eliminate MPtb in milk could only be accomplished by pasteurizing naturally infected milk using a commercial pasteurizer operated under turbulent flow. This is impractical in most situations though because of the large quantities of infected milk that would be required in experiments and other logistical problems.
The holding tubes of commercial HTST milk pasteurizers may be operated under laminar or turbulent flow conditions, which depend on the geometry of the tube, flow rate of the fluid, and the viscosity and density of the fluid. The Reynolds number, NRe, frequently is used to distinguish the type of flow in the holding tube of a pasteurizer. It is defined by NRe = dv
/µ, where d is pipe diameter, v is the average velocity of the fluid flowing through the pipe,
is fluid density, and µ is fluid viscosity (Bird et al., 2002). The degree of pasteurization is rarely uniform for all portions of a product that pass through a pasteurizer (Rao and Loncin, 1974a) and depends on the FMP time and the residence time distribution (RTD) of particles flowing through it.
Hasting et al. (2001) calculated NRe for holding tubes of several large-scale commercial HTST pasteurizers and compared them with the NRe, calculated assuming long tube geometry, of the holding tubes of pasteurizers used in pilot-scale HTST pasteurization experiments for Mptb in milk (Hope et al., 1997; Stabel et al., 1997). The Reynolds number for the commercial holding tubes was well above 2100, indicative of turbulent flow for straight pipes, and appeared to approach plug flow conditions with NRe >10,000. The Reynolds number for the small-scale pasteurizer used by Stabel et al. (1997) was 400 and that used by Hope et al. (1997) ranged from 54 to 125 for a 12-mm i.d. tube. For flow in a long, straight pipe, these values are indicative of laminar flow. Even though flow was laminar by calculation of NRe, Hope et al. (1997) and Stabel et al. (1997) reported inactivation of Mptb in artificially infected milk in most runs while Grant et al. (2000) showed that MPtb in naturally infected milk is capable of surviving commercial HTST pasteurization if present in raw milk in sufficient numbers.
However, NRe is highly geometry dependent, and the use of the long, straight pipe assumption to calculate NRe for the holding tubes of the pilot-scale pasteurizers may result in incorrect conclusions on the effectiveness of pasteurization for microorganisms in milk if the data are extrapolated to commercial HTST operation. The holding tubes of commercial pasteurizers are typically several meters long with bends at each end so that the whole assembly fits in as small a space as possible. The assumption of straight pipe geometry is reasonably accurate for calculating NRe. The newest pilot-scale pasteurizers typically have short helical tubes that can have the effect of secondary circulation, reducing the spread of residence times typically observed in laminar flow (Ruthven, 1971). The actual flow pattern through a process vessel, such as a pasteurizer and the holding tube, is between the plug flow and mixed flow ideals (Rao and Loncin, 1974a).
With the recent outbreak of Foot-and-Mouth Disease (FMD) in England, methods used to determine the effectiveness of pasteurization for elimination of FMD virus in milk have been reexamined (Tomasula and Konstance, 2004). Foot-and-Mouth Disease is not a public health threat but is highly contagious to cloven-hoofed animals. In studies conducted by Hyde et al. (1975), a simulated HTST method was used in which milk obtained from FMD virus-infected cows was heated to 72°C in bottles immersed in a constant temperature bath, held for 15 s, and then cooled. The FMD virus was not completely inactivated in the whole or skim milk samples. A later study (Walker et al., 1984) reported that the virus was inactivated at times >20 min and temperatures >100°C when a simulated HTST method was used and the temperature was 148°C for 2.5 s when a continuous flow UHT method was used. The thermal treatment that the infected milk samples received under pasteurization condition temperatures is difficult to ascertain from the data that were presented in both studies.
The objective of this study was to demonstrate a method for determination of FMP time and RTD of particles for a pilot-scale pasteurizer so that the thermal treatment that milk and any pathogens it may contain are known. This is in anticipation of conducting studies on HTST treatment of milk infected with FMD virus and other pathogens, including spore-forming pathogens, such as Bacillus anthracis. The method developed here is general enough for application to all pilot-scale HTST pasteurizers.
| MATERIALS AND METHODS |
|---|
|
|
|---|
|
Holding Tubes
The test solution (water, milk, or brine solution) exits the plate and frame heat exchanger and enters a holding tube that is used to achieve the time-temperature requirements for pasteurization. The solution then returns to the cooling side of the pasteurizer via another flexible tube. This flexible tube contributes to the holding section. Two holding tubes were used in separate experiments: a short tube that is designated 15-s hold and a long tube that is designated 45-s hold by the manufacturer if flow rates of 9.87 and 18.97 L/h are used, respectively. The volume of the short 15-s hold tube is 35.7 mL plus 23 mL for the flexible tube (total = 58.7 mL). The volume of the long 45-s hold tube is 252.2 mL plus 23 mL for the flexible tube (total = 275.2 mL). The volume of the plate and frame heat exchanger is 114 mL. The pump volume, including a flexible tube connecting the pump to the pasteurizer, is 220 mL. A flow rate of 9.87 L/h was used to achieve a 15-s hold time for the short tube. The actual holding time for the 15-s hold tube is then obtained by dividing the volume of the hold tube plus the volume of the flexible tube section by the flow rate or 21.5 s. The flow rate used for the 45-s hold tube was 18.97 L/h, and the actual holding time is 52.2 s. The diameter of both holding tubes is 9.65 mm. The flow rate was determined by a linear calibration of the pump flow rate as a function of the pump setting. The value of the correlation coefficient, r, was 0.99.
Test Solutions
The brine water test solution was prepared by dissolving 200 g of NaCl in 1000 mL of deionized water (3.5 M). The brine milk test solutions were prepared by dissolving approximately 14 g of NaCl in 2000 mL (0.12 M) of locally purchased whole milk until the conductivity was in the range of 12 to 13.5 mS. The solutions were allowed to sit for approximately 30 min prior to experiments. Conductivity was determined using a TDSTestr 20 conductivity meter (Cole Parmer Instrument Co., Niles, IL). The added Na ion exchanges with Ca in the milk (Famelart et al., 1999). Most of the exchange happens quickly (diffusion controlled), but the residual exchange creates a small amount of instability in the conductivity readings.
Determination of FMP and RTD
The method reported here uses a tracer method for determination of the FMP in which the brine solution is directly fed into the pasteurizer. In a typical experiment, water (or milk) is pumped through the system until steady state is reached. When the surface of the feed is just observed at the inlet to the pump, a sudden step change is introduced to the system by pouring the tracer solution into the feed funnel.
Brine water samples were collected in 4.5-mL (nominal) glass vials as the stream exited the holding tube and the flexible tubing that would be connected to the cooling section during an actual pasteurization run. Twenty vials were used in all. Two were used for the tracer control samples. The other 18 samples were collected continuously to ensure collection of zero or first particle samples. After all samples were collected, the tracer solution was allowed to drain into the pump, and the feed funnel was filled with fresh test fluid, water, or milk to begin the next experiment. The system was purged until the conductivity of the exit fluid indicated no elevated salinity. Experiments were performed in duplicate.
Brine milk samples were collected in 10-mL (nominal) glass vials. Seventeen vials were used. Two extra vials were used for the tracer control samples, and one extra vial was used for a zero or initial milk sample. The 17 samples were collected continuously.
After all samples were collected, the tracer solution was allowed to drain into the pump, and the feed funnel was filled with fresh test milk. The system was purged until the conductivity of the exit fluid indicated no elevated salinity.
Time for each vial for the FMP time study was determined as the time the vial first started to fill with sample. Time for each vial for the RTD study was determined as the median time the vial filled with sample.
To complete the RTD study, the previously described procedure was repeated, collecting brine water or milk samples leaving the pump. Then, samples were collected leaving the pump followed by the plate and frame heat exchanger.
To determine the change in conductivity of the water samples, each sample was poured into a test beaker. The sample vial was filled with fresh tap water and added to the sample. The dilution had the effect of cooling the sample and achieving a sufficient volume of liquid to measure conductivity. All samples were treated identically, and it was the change in conductivity that was used so that there were no effects caused by this dilution. Conductivity of the milk samples was determined as is because there was sufficient volume to test.
| RESULTS AND DISCUSSION |
|---|
|
|
|---|
The tracer data obtained using the brined water and milk samples are used to calculate values of F, the ratio of brine concentration leaving the holding tube divided by the initial concentration of brine in the sample stream, at each sampling time, for the flow rates of 9.87 and 18.97 L/h. Values of F were also calculated for the fluid leaving the pump, the pump plus the plate and frame heat exchanger, and the pump plus the plate and frame heat exchanger and the holding tube. The F values were then used to calculate the internal age distribution (Levenspiel, 1972, 1999), where I = 1 F and represents the age of particles still in the equipment.
Figures 2
and 3
plot the internal age distribution function, I, as a function of time for the 2 flow rates. The curve represents the downstream response of the process to the upstream step change in input with addition of brine solution. The curve ranges between 0 and 1. The time for the first particle exiting the process corresponds to the intercept at I = 1. Some preliminary RTD data (not shown) were interpolated to establish approximately when the RTD curve would break, namely, when the value of I dropped below 1.0. Then, the reported RTD data were collected in the proper range so the samples collected would include the first particle. Interpolation of the RTD curves confirmed the validity of the first particle values.
|
|
|
If NRe is calculated assuming that the hold tubes are approximated by a long, straight pipe geometry (Hasting et al., 2001), then NRe is approximately 170 for the short hold tube and 330 for the long hold tube. Therefore, because the NRe for both tubes indicates laminar flow, the FMP would be one-half of the nominal or average residence time. For the short hold section at the lower flow rate of 9.87 L/h, this would be 0.5 x 21.5 s or 10.8 s, compared with a value of 18.6 s obtained by FMP analysis, and for the long hold section at the higher flow rate of 18.97 L/h, this would be 0.5 x 52.2 s or 26.1 s compared with a value of 36 s. This confirms that NRe is not a valid predictor of the FMP time and RTD in the hold tubes.
RTD
Flow through the plate and frame heat exchanger of the pasteurizer and hold tubes is most likely a combination of plug and back-mixed flow with a small component of undefined flow. More important is knowledge of how long the individual molecules reside in the plate and frame heat exchanger and hold tubes or the distribution of residence times in the flowing fluid (Levenspiel, 1999).
Grijspeerdt et al. (2003) used computational fluid dynamics to study the hydrodynamics of milk flow in plate heat exchangers. Their analysis elucidated the movement of flow regimens between the walls and bulk fluid flow. It also indicated areas most prone to fouling. Computational fluid dynamics showed that the influence of the inlet flow extends only up to 3 corrugations. Therefore, we can safely assume the flow leaving the plate heat exchanger and entering either the short or long hold section of our pasteurization equipment has reached a steady-state defined flow. A RTD study of the hold sections should be independent of the plate heat exchanger.
Therefore, the RTD was determined for the plate and frame heat exchanger with no hold section and then with each hold section. The volume fractions of plug and back-mixed flow in the pasteurizer without any hold section plus with each hold section was also determined.
Figures 4
and 5
plot the internal age distribution function, I (Levenspiel, 1999), as a function of the dimensionless term, reduced time, defined as sample time divided by the nominal residence time for the 2 flow rates. Table 2
presents all of the results of the RTD analysis normalized as fraction of back-mixed and plug flow through the entire system to the exit of the section noted. Table 1
included the correlation coefficient for the back-mixed section of the curve (negative slope). However, a better estimate for the error of the RTD data is the amount of normalization required. Table 2
includes the normalization factor or summations of the fractions of back-mixed and plug flows before normalization. It must be kept in mind that a very small error in the slope of the curve has a large effect on the overall results. Errors of 10 to 15% are common. The 2 flow rates, 9.87 and 18.97 L/h, corresponding to the flow rates used to obtain the nominal residence time indicated for the each hold section (21.5 s for the short hold section and 52.2 s for the long hold section) were used.
|
|
|
Using the short hold section and low flow rate, the normalized volume fractions were 0.53 plug flow and 0.47 back-mixed flow for water and 0.50 plug flow and 0.50 back-mixed flow for milk. The normalized volume fractions using the long hold section and high flow rate were 0.72 plug flow and 0.28 back-mixed flow for water and 0.68 plug flow and 0.32 back-mixed flow for milk. The milk and water data agree within 5% error.
These data were used to calculate the volume corresponding to plug and back-mixed flow through the various parts of the process. The difference between the volumes through a section minus the volumes through the previous section indicates the normalized volume fraction for the specific section. For instance, using milk with a flow rate of 9.87 L/h and short hold time, plug flow accounted for 196.5 mL. (0.50 x 393 mL). Back mixed flow accounted for 196.5 mL. There was a 165-mL plug flow and a 169-mL back-mixed flow from the pasteurizer. The difference gives the specific volumes corresponding to the short hold section, 32 mL plug and 27 mL back mixed.
With the volume specific to each section, the volume fraction of each type flow for each section starting with the plate and frame heat exchanger was calculated. Table 3
presents these data. It is noteworthy that milk flow was >80% plug flow in the long hold section at both flow rates. Water was >72% plug flow in all cases. However, the milk was only 55 to 56% plug flow in the short hold section.
|
/µ, where De is the equivalent diameter and is equal to 2 x the gap between the plates, is 75 for the lower flow rate of 9.87 L/h and is 150 at the higher flow rate of 18.97 L/h. For plate heat exchangers, the turbulent zone for NRe is between 10 and 400. At steady state, the composition of product or test fluid entering the hold section will be equal to that in the feed. The fluid is heated to the pasteurization temperature during come-up time in the plate and frame heat exchanger pasteurizer, but only the hold time is used to determine thermal treatment. Analysis of the pasteurization process is specific to the hold section consisting of the hold tube and the tube connecting the hold tube to the cooling side of the pasteurizer.
| Calculation of D Values Obtained from Small-Scale HTST Pasteurization Experiments |
|---|
|
|
|---|
It is recommended that instead of calculating D values through assumption of first-order kinetics and using the models referenced above for HTST pasteurization, that experiments be conducted in flow equipment to ensure that the destruction of the organism occurs at times greater than or equal to that of the FMP to establish the minimum holding time necessary for destruction of the microorganism. In this way, the exact time it takes to either reduce the numbers of a microorganism or eliminate it completely may be determined.
| CONCLUSIONS |
|---|
|
|
|---|
| ACKNOWLEDGEMENTS |
|---|
|
|
|---|
| FOOTNOTES |
|---|
Received for publication April 29, 2004. Accepted for publication June 7, 2004.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. M. Tomasula, M. F. Kozempel, R. P. Konstance, D. Gregg, S. Boettcher, B. Baxt, and L. L. Rodriguez Thermal Inactivation of Foot-and-Mouth Disease Virus in Milk Using High-Temperature, Short-Time Pasteurization J Dairy Sci, July 1, 2007; 90(7): 3202 - 3211. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |