JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J. Dairy Sci. 2009. 92:5304-5313. doi:10.3168/jds.2009-2246
© 2009 American Dairy Science Association ®

OPEN ACCESS ARTICLE
This Article
Free Via Open Access
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Interpretive Summary
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Cecchinato, A.
Right arrow Articles by Carnier, P.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cecchinato, A.
Right arrow Articles by Carnier, P.

Mid-infrared spectroscopy predictions as indicator traits in breeding programs for enhanced coagulation properties of milk

A. Cecchinato1, M. De Marchi, L. Gallo, G. Bittante and P. Carnier

Department of Animal Science, University of Padova, Viale dell’Università 16, 35020 Legnaro, Padova, Italy

1 Corresponding author: alessio.cecchinato{at}unipd.it

The aims of this study were to investigate variation of milk coagulation property (MCP) measures and their predictions obtained by mid-infrared spectroscopy (MIR), to investigate the genetic relationship between measures of MCP and MIR predictions, and to estimate the expected response from a breeding program focusing on the enhancement of MCP using MIR predictions as indicator traits. Individual milk samples were collected from 1,200 Brown Swiss cows (progeny of 50 artificial insemination sires) reared in 30 herds located in northern Italy. Rennet coagulation time (RCT, min) and curd firmness (a30, mm) were measured using a computerized renneting meter. The MIR data were recorded over the spectral range of 4,000 to 900 cm–1. Prediction models for RCT and a30 based on MIR spectra were developed using partial least squares regression. A cross-validation procedure was carried out. The procedure involved the partition of available data into 2 subsets: a calibration subset and a test subset. The calibration subset was used to develop a calibration equation able to predict individual MCP phenotypes using MIR spectra. The test subset was used to validate the calibration equation and to estimate heritabilities and genetic correlations for measured MCP and their predictions obtained from MIR spectra and the calibration equation. Point estimates of heritability ranged from 0.30 to 0.34 and from 0.22 to 0.24 for RCT and a30, respectively. Heritability estimates for MCP predictions were larger than those obtained for measured MCP. Estimated genetic correlations between measures and predictions of RCT were very high and ranged from 0.91 to 0.96. Estimates of the genetic correlation between measures and predictions of a30 were large and ranged from 0.71 to 0.87. Predictions of MCP provided by MIR techniques can be proposed as indicator traits for the genetic enhancement of MCP. The expected response of RCT and a30 ensured by the selection using MIR predictions as indicator traits was equal to or slightly less than the response achievable through a single measurement of these traits. Breeding strategies for the enhancement of MCP based on MIR predictions as indicator traits could be easily and immediately implemented for dairy cattle populations where routine acquisition of spectra from individual milk samples is already performed.

Key Words: milk coagulation property • mid-infrared spectroscopy • heritability • genetic correlation







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Dairy Science Association ®.