JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Interpretive Summary
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaylegian, K. E.
Right arrow Articles by Barbano, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaylegian, K. E.
Right arrow Articles by Barbano, D. M.
J. Dairy Sci. 89:2817-2832
© American Dairy Science Association, 2006.

Calibration of Infrared Milk Analyzers: Modified Milk Versus Producer Milk1

K. E. Kaylegian*, G. E. Houghton{dagger}, J. M. Lynch*, J. R. Fleming{ddagger} and D. M. Barbano*,2

* Northeast Dairy Foods Research Center Department of Food Science, Cornell University Ithaca, NY 14853
{dagger} Kestrel Software Consulting, Berkshire, NY 13736
{ddagger} USDA, Agricultural Marketing Service, Texas Milk Marketing Area, P. O. Box 110939 Carrollton 75011

2 Corresponding author: dmb37{at}cornell.edu

Mid-infrared (MIR) milk analyzers are traditionally calibrated using sets of preserved raw individual producer milk samples. The goal of this study was to determine if the use of sets of preserved pasteurized modified milks improved calibration performance of MIR milk analyzers compared with calibration sets of producer milks. The preserved pasteurized modified milk sets exhibited more consistent day-to-day and set-to-set calibration slope and intercept values for all components compared with the preserved raw producer milk calibration sets. Pasteurized modified milk calibration samples achieved smaller confidence interval (CI) around the regression line (i.e., calibration uncertainty). Use of modified milk calibration sets with a larger component range, more even distribution of component concentrations within the ranges, and the lower correlation of fat and protein concentrations than producer milk calibration sets produced a smaller 95% CI for the regression line due to the elimination of moderate and high leverage samples. The CI for the producer calibration sets were about 2 to 12 times greater than the CI for the modified milk calibration sets, depending on the component. Modified milk calibration samples have the potential to produce MIR milk analyzer calibrations that will perform better in validation checks than producer milk-based calibrations by reducing the mean difference and standard deviation of the difference between instrument values and reference chemistry.

Key Words: infrared milk analyzer • calibration • modified milk




This article has been cited by other articles:


Home page
J DAIRY SCIHome page
K. E. Kaylegian, J. M. Lynch, J. R. Fleming, and D. M. Barbano
Lipolysis and Proteolysis of Modified and Producer Milks Used for Calibration of Mid-Infrared Milk Analyzers
J Dairy Sci, February 1, 2007; 90(2): 602 - 615.
[Abstract] [Full Text] [PDF]


Home page
J DAIRY SCIHome page
K. E. Kaylegian, J. M. Lynch, G. E. Houghton, J. R. Fleming, and D. M. Barbano
Modified versus producer milk calibration: mid-infrared analyzer performance validation.
J Dairy Sci, August 1, 2006; 89(8): 2833 - 2845.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Dairy Science Association ®.