JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Interpretive Summary
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gonzalo, C.
Right arrow Articles by Primitivo, F. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gonzalo, C.
Right arrow Articles by Primitivo, F. S.
J. Dairy Sci. 89:4613-4619
© American Dairy Science Association, 2006.

Evaluation of the Overall Accuracy of the DeLaval Cell Counter for Somatic Cell Counts in Ovine Milk

C. Gonzalo1, B. Linage, J. A. Carriedo, F. de la Fuente and F. San Primitivo

Departamento de Producción Animal, Facultad de Veterinaria, Universidad de León, 24071-León, Spain

1 Corresponding author: dp2cga{at}unileon.es

The DeLaval cell counter (DCC) is a portable device designed for on-farm somatic cell count (SCC) analysis in bovine milk. This study evaluated the performance of the DCC when analyzing ovine milk. A total of 29 composite ovine milk samples, ranging between 20 x 103 and 2,200 x 103 cells/mL, were divided into 15 aliquots/milk sample corresponding to 5 SCC methods using 3 types of preservation (unpreserved, azidiol, and bronopol). The SCC methods were the Fossomatic (FSCC), the DCC in undiluted samples, and the DCC in samples diluted 1:1 in 3 different types of diluents (PBS + Triton X-100, PBS + ethidium bromide + Triton X-100, and PBS + propidium iodide + Triton X-100). All analyses were carried out in duplicate. In addition, each sample was analyzed in quadruplicate by the direct microscopic method (DMSCC) using Pyronin Y-methyl green as a stain. Comparison of methods was based on overall accuracy studies (means comparison, repeatability, and regression studies vs. DMSCC and FSCC as reference methods). The DCC methods used to analyze milk samples diluted in staining solution (with ethidium bromide or propidium iodide) showed large coefficients of regression (b = 0.91 to 1.01) and correlation (r > 0.99) when compared with the DMSCC and FSCC methods. In these samples the DCC gave repeatability values (sr = 33 to 48 x 103 cells/mL) similar to the DMSCC (sr = 36 x 103 cells/mL), and their log SCC means (5.52 to 5.54) did not differ from the reference value (5.54). However, undiluted samples analyzed by the DCC method showed large standard deviations of repeatability and SCC values lower than those by the DMSCC or FSCC methods, probably because of the high solids content in ovine milk. The type of preservation did not affect the outcomes. Consequently, the DCC was determined to be accurate when analyzing diluted ovine milk based on comparison with the SCC reference methods.

Key Words: sheep milk • somatic cell count • DeLaval cell counter • accuracy




This article has been cited by other articles:


Home page
J DAIRY SCIHome page
C. Gonzalo, B. Linage, J. A. Carriedo, and L. F. De La Fuente
Short Communication: Evaluation of the Overall Accuracy of the DeLaval Cell Counter for Somatic Cell Count in Ovine Milk: Effect of Soak Time in Diluted and Undiluted Milk Samples
J Dairy Sci, August 1, 2008; 91(8): 3114 - 3118.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Dairy Science Association ®.