JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Interpretive Summary
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berman, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berman, A.
J. Dairy Sci. 86:3605-3610
© American Dairy Science Association, 2003.

Effects of Body Surface Area Estimates on Predicted Energy Requirements and Heat Stress

A. Berman

Department of Animal Science, Hebrew University, Rehovot 76100, Israel

The 0.09 x W0.67 equation (where W = weight in kilograms) used to estimate body surface area (SA) in cattle energy requirements models was developed using measurements of sheep that weighed between 24 and 38 kg. The SA estimates it produced were compared with those of the equation 0.14 x W0.57, based on Holstein cattle weighing 41 to 617 kg. The estimate of SA produced by the first equation was 23% greater for a 650-kg cow than that obtained by the second equation. The impact of SA estimates on thermal comfort range and development of cold and heat stress effects was calculated, using a thermal balance model, for a 600-kg cow producing 35 kg/d. Predicted metabolic heat production increment at -10°C ambient temperature with 0.5 m/s wind velocity was 0.44 Mcal/d and 1.21 Mcal/d by the first and second equation, respectively. Predicted lower critical temperature (LCT) was -8.7°C by the first equation and -0.6°C by the second equation, an 8°C difference. The LCT difference between SA estimates increased from 4.6 to 9.4°C, with milk production rising from 10 to 45 kg/d. By the first equation, skin nonevaporative heat loss started to decrease at 15°C and became close to nil at and ambient temperature of 35°C, whereas by the second equation, respective values were 10°C and 39°C, a 5°C shift in the estimated temperature at which thermal stress would start developing. The larger SA and skin water loss predicted by the first equation reduced by 50% the respiratory heat loss involved in maintenance of thermal balance at higher temperatures for a 600-kg cow. The second equation seems preferable for Holstein SA estimation since it is based on Holstein cattle data. It provides more adequate estimates of energy requirement in the cold and of heat stress relief needs for Holstein cattle.

Key Words: body surface • energy requirements • heat stress • thermal comfort

Abbreviation key: CNCPS = Cornell Net Carbohydrate and Protein System, Hcr = combined convective and radiant heat loss, HP = metabolic heat production, INS = total body insulation, LCT = lower critical temperature, SA = body surface area




This article has been cited by other articles:


Home page
J ANIM SCIHome page
A. Berman
Estimates of heat stress relief needs for Holstein dairy cows
J Anim Sci, June 1, 2005; 83(6): 1377 - 1384.
[Abstract] [Full Text] [PDF]


Home page
J DAIRY SCIHome page
A. Berman
Tissue and External Insulation Estimates and Their Effects on Prediction of Energy Requirements and of Heat Stress
J Dairy Sci, May 1, 2004; 87(5): 1400 - 1412.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Dairy Science Association ®.