JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 85 No. 6 1502-1508
© 2002 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ahmed, A. F.
Right arrow Articles by Misk, N. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ahmed, A. F.
Right arrow Articles by Misk, N. A.

Effect of Feeding Frequency and Route of Administration on Abomasal Luminal pH in Dairy Calves Fed Milk Replacer

A. F. Ahmed 1, P. D. Constable 2, and N. A. Misk 1

1 Department of Veterinary Surgery, Faculty of Veterinary Medicine, Assiut University, Assiut, Egypt
2 Department of Veterinary Clinical Medicine, University of Illinois, 1008 W. Hazelwood, Urbana, IL 61802

The aim of this study was to determine the effect of feeding frequency and route of administration on abomasal luminal pH in suckling calves. Six male dairy calves with cannulae in the abomasal body were administered the following six treatments in a randomized crossover design: 24 h fasting, suckling of a high-quality milk replacer (all-milk protein; 12% of body weight [BW]/d) at 12-h (2x), 8-h (3x), 6-h (4x), and 3-h (8x) intervals, and ruminal intubation of milk replacer (12% of body weight/day) at a 12-h (2x) interval. Abomasal luminal pH was measured every second for 24 h with miniature glass pH electrodes. Least squares mean 24-h fasting abomasal luminal pH was 1.73, whereas mean 24-h pH after suckling and intubation of milk replacer every 12 h were higher at 3.44 and 3.17, respectively. Increasing the frequency of milk replacer suckling to 3x, 4x, and 8x increased mean 24-h abomasal luminal pH; however, there was no difference in mean 24-h pH between 3x (3.69), 4x (3.64), and 8x (3.67) suckling. The percentage of the 24-h recording period that abomasal luminal pH was > 3.0 was 0, 49, 53, 61, 61, and 71% for fasting, 2x intubation of milk replacer, and 2x, 3x, 4x, and 8x suckling of milk replacer, respectively. Increasing the frequency of milk replacer suckling may be efficacious in the prophylaxis of abomasal ulceration in milk-fed calves.

Key Words: calf • feeding frequency • milk replacer • abomasal ulceration

Submitted on October 10, 2001
Accepted on December 12, 2001







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Dairy Science Association ®.