JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 83 No. 9 1939-1945
© 2000 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eshkenazi, I.
Right arrow Articles by Rishpon, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eshkenazi, I.
Right arrow Articles by Rishpon, J.

A Three-Cascaded-Enzymes Biosensor to Determine Lactose Concentration in Raw Milk

I. Eshkenazi 1, E. Maltz 2, B. Zion 2, and J. Rishpon 1

1 Department of Molecular Microbiology and Biotechnology, Tel-Aviv University, Ramat-Aviv 69978, Israel
2 Institute of Agricultural Engineering, Agricultural Research Organization, The Volcani Center, Bet Dagan 50250, Israel

The increasing demand for on-line measurement of milk composition directs science and industry to search for practical solutions, and biosensors may be a possibility. The specific objective of this work was to develop an electrochemical biosensor to determine lactose concentration in fresh raw milk. The sensor is based on serial reactions of three enzymes—ß-galactosidase, glucose oxidase, and horseradish peroxidase—immobilized on a glassy carbon electrode. The sequential enzymatic reactions increase the selectivity and sensitivity of the sensor. The sensor requires dilution of the raw milk and the addition of 5-aminosalicylic acid. Lactose concentrations in raw milk measured by the sensor were in good agreement with those measured by a reference laboratory using infrared technology. The results were obtained in milk samples that varied in fat and protein composition. From the results, we conclude that an electrochemical biosensor for determination of lactose concentration in fresh raw milk can be developed, and that the biosensor presented in this study maintained the qualities required for further development into an online sensor in the milking parlor.

Key Words: lactose • biosensor • raw milk

Submitted on November 16, 1999
Accepted on March 7, 2000







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Dairy Science Association ®.