JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 81 No. 3 817-820
© 1998 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Murphy, S. C.
Right arrow Articles by Boor, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Murphy, S. C.
Right arrow Articles by Boor, K. J.

Evaluation of Adenosine Triphosphate-Bioluminescence Hygiene Monitoring for Trouble-Shooting Fluid Milk Shelf-Life Problems

S. C. Murphy 1, S. M. Kozlowski 1, D. K. Bandler 1, and K. J. Boor 1

1 Department of Food Science, Cornell University, Ithaca, NY 14853

An ATP-bioluminescence hygiene monitoring system was used to evaluate food contact surfaces in four fluid milk plants experiencing shelf-life problems. Postpasteurization surfaces, including gaskets, pipe fittings, valves, filler parts, and hand-washed items, were evaluated. Swab results, measured in relative light units proportional to total recovered ATP, were compared with results from the standard method of microbiological swab contact for adjacent sites of equal area. Microbiological procedures included standard plate count, coliform count, and Gram-negative bacteria count. Standard plate counts were <1, 1 to 50, and >50 cfu in 65, 22, and 13% of swabbed sites of <100 RLU (relative light units); in 9, 36, and 55% of sites of 100 to 150 RLU; and in 22, 18, and 60% of sites of >150 RLU, respectively. Thirteen sites were found with standard plate counts >10,000 cfu per site and identified with the hygiene monitoring system (>150 RLU). Gram-negative bacteria were the dominant bacterial type in a majority of these samples. Gram-negative bacteria were detected in a total of 22 sites tested; mean counts were 2100 cfu per site for Gram-negative bacteria and 20 cfu per site for coliform bacteria. Although limited to use on accessible sites, the hygiene monitoring system proved to be an effective, rapid tool for identifying the possible sources of postpasteurization contamination in the fluid milk plants evaluated.

Key Words: shelf-life • adenosine triphosphate-bioluminescence • hygiene monitoring • Gram-negative bacteria

Submitted on July 9, 1997
Accepted on October 14, 1997




This article has been cited by other articles:


Home page
J DAIRY SCIHome page
C. H. White, J. Wilson, and M. W. Schilling
An investigation of the use of the MicroFoss as an indicator of the shelf life of pasteurized fluid milk.
J Dairy Sci, July 1, 2006; 89(7): 2459 - 2464.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Dairy Science Association ®.