JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 81 No. 1 25-30
© 1998 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schlesser, J. E.
Right arrow Articles by Negiz, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schlesser, J. E.
Right arrow Articles by Negiz, A.

Acquisition, Storage, and Review of Safety Data from a Commercial System for High Temperature, Short Time Pasteurization

J. E. Schlesser 1, G. Lynn 1, D. J. Armstrong 1, A. Cinar 1, P. Ramanauskas 1, and A. Negiz 1

1 United States Food and Drug Administration, National Center for Food Safety and Technology, 6502 South Archer Road, Summit-Argo, IL 60501

A high temperature, short time (HTST) pasteurization system was equipped with electronic sensors to determine the temperature, pressure, flow rate, and position of the flow diversion valve. A computer for data acquisition was wired to the sensors to monitor and to record processing conditions related to public health. The processing conditions were stored in safety files on the hard drive of the computer, transferred weekly to a tape drive, and stored. The processing conditions of the HTST system were monitored for 270 d to determine the accuracy and reliability of the data acquisition system. The size of the HTST safety files ranged from 6.2 to 9.1 MB when the sensors were monitored every second. The file size was reduced to <1.8 MB when the monitoring frequency was increased to every 5 s. To determine accuracy, the temperatures recorded by the data acquisition system were compared with the temperatures recorded by an electronic recorder controller.

To determine reliability, changes in the position of the flow diversion valve were examined to identify process deviations and were compared with the event marker on circular charts. The review of the data file by the actual time method was an effective alternative to the electronic recorder controller for monitoring the completeness of data in the safety files. Off-line review to determine reliability required approximately 10 min/d of records.

Key Words: data acquisition • dairy • pasteurization

Submitted on November 20, 1996
Accepted on September 2, 1997







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Dairy Science Association ®.