JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 75 No. 11 3210-3217
© 1992 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barbano, D. M.
Right arrow Articles by Lynch, J. M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Barbano, D. M.
Right arrow Articles by Lynch, J. M.

Crude and Protein Nitrogen Bases for Protein Measurement and Their Impact on Current Testing Accuracy

David M. Barbano 1 and Joanna M. Lynch 1

1 Northeast Dairy Foods Research Center, Department of Food Science, Cornell University, Ithaca, NY 14853

As the value of milk protein increases, accuracy of measurement of milk protein content becomes more important. Traditionally, milk protein content has been estimated from total N. However, about 5 to 6% of milk total N is not associated with protein and varies among farms, regions, and seasons. Currently, most milk protein testing is done with infrared milk analyzers using Kjeldahl total N as a basis for protein calibration. Analytical errors occur as a result of using total N as the basis for protein calibration of infrared analyzers instead of true protein. These errors are caused by two factors: differences in mean NPN as a percentage of total N from one set of calibration samples to the next and differences in NPN as a percentage of total N between samples within each set of calibration milks. Examples of the magnitude of errors created by these factors are calculated using actual data from industry laboratories. The accuracy of protein testing using infrared analyzers for payment and record-keeping purposes could be improved substantially by using true protein as a basis for calibration instead of total N.

Key Words: protein • infrared milk analysis • nonprotein nitrogen

Submitted on September 30, 1991
Accepted on February 10, 1992




This article has been cited by other articles:


Home page
J DAIRY SCIHome page
K. E. Kaylegian, G. E. Houghton, J. M. Lynch, J. R. Fleming, and D. M. Barbano
Calibration of infrared milk analyzers: modified milk versus producer milk.
J Dairy Sci, August 1, 2006; 89(8): 2817 - 2832.
[Abstract] [Full Text] [PDF]


Home page
J DAIRY SCIHome page
D. M. Barbano and J. M. Lynch
Major advances in testing of dairy products: milk component and dairy product attribute testing.
J Dairy Sci, April 1, 2006; 89(4): 1189 - 1194.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Dairy Science Association ®.