JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 73 No. 10 2774-2784
© 1990 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nickerson, S. C.
Right arrow Articles by Watts, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nickerson, S. C.
Right arrow Articles by Watts, J. L.

Effects of Novel Intramammary Device Models on Incidence of Mastitis After Experimental Challenge

S. C. Nickerson 1, R. L. Boddie 1, W. E. Owens 1, and J. L. Watts 1

1 Mastitis Research Laboratory, Hill Farm Research Station, Louisiana Agricultural Experiment Station, Louisiana State University Agricultural Center, Route 1, Box 10, Homer 71040

First-calf heifers were fitted with five different intramammary device models prior to, or within 2 mo after parturition. Each model represented an increase in the weight of the device to be supported by the epithelial cells of the gland cistern. Each model was tested in four animals by placing devices in two quarters while remaining quarters served as controls. Foremilk and stripping quarter secretion samples were collected prior to device placement and weekly thereafter and analyzed for total and differential cell counts, bacteriologic status, and NAGase activity. During the prebacterial challenge treatment period, foremilk and stripping SCC as well as percentage of neutrophils and NAGase activity in most device-fitted quarters remained significantly elevated over controls. Frequency of naturally occurring intramammary infection during the prechallenge period was lowest in quarters fitted with Models 2, 4, and 5. Frequency of infection with coagulase-negative staphylococci also tended to be lower in quarters fitted with Models 2, 4, and 5. Approximately 4 mo after device placement, all quarters were challenged by intracisternal inoculation with about 565 cfu Streptococcus uberis. Results across all models combined showed that although mean foremilk and stripping SCC and percentage of neutrophils were significantly elevated in device-fitted quarters immediately prior to bacterial challenge, only Model 4 showed a protective effect. Several models were superior to others in elevating SCC and percentage of neutrophils, but no differences in susceptibility to Strep. uberis infection were observed among models based on these cytological characteristics.

Key Words: intramammary device • mastitis • somatic cells

Submitted on March 5, 1990
Accepted on May 14, 1990




This article has been cited by other articles:


Home page
J DAIRY SCIHome page
H. Dosogne, F. Vangroenweghe, J. Mehrzad, A. M. Massart-Leen, and C. Burvenich
Differential Leukocyte Count Method for Bovine Low Somatic Cell Count Milk
J Dairy Sci, March 1, 2003; 86(3): 828 - 834.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American Dairy Science Association ®.