JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 47 No. 7 761-765
© 1964 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmidt, G. H.
Right arrow Articles by Guthrie, R. S.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Schmidt, G. H.
Right arrow Articles by Guthrie, R. S.

Effect of Teat-end Vacuum Fluctuations on Milking Rate and Mastitis1

G. H. Schmidt, K. O. Switzer, R. W. Guest and R. S. Guthrie

Departments of Animal Husbandry, Agricultural Engineering, and Veterinary Medicine and Obstetrics, Cornell University, Ithaca, New York

ABSTRACT

Two groups of eight cows each were milked for 25-day periods with either a regular milking machine or one in which the milk was elevated 6 ft before it was returned to the milker pail. The purpose of this experiment was to determine the effect of teat-end vacuum fluctuations resulting from the elevation of milk on the incidence of udder irritation and the rate of milking. At the end of the 25-day period the treatments were reversed and the study was continued for another 25-day period. One group of cows was free from all mastitis organisms, whereas the second group had 12 quarters with persistent mastitis infections. The maximum vacuum fluctuations were measured during the maximum rate of flow and they averaged 2.81 and 3.36 in. Hg for the control and elevated-line milkings, respectively. The cows milked with the elevated line had a significantly longer total milking time, a lower maximum rate of flow, and the vacuum level was lower in comparison to when they were milked with the control machine. No difference was noted in the California Mastitis Test (CMT) ratings or leucocyte counts due to the different milking systems; however, the CMT ratings were significantly higher during the second 25-day period than the first.


FOOTNOTES

1 Supported in part by the Grange League Federation, Ithaca, New York.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1964 by the American Dairy Science Association ®.