JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 43 No. 5 607-613
© 1960 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Erb, R. E.
Right arrow Articles by Ashworth, U. S.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Erb, R. E.
Right arrow Articles by Ashworth, U. S.

Comparative Accuracy of the Plastic Bead Method of Golding and the Lactometer Method of Watson for Routine Determination of Solids-not-fat in Milk1

R. E. Erb, L. J. Manus and U. S. Ashworth

Department of Dairy Science, Washington State University, Pullman

ABSTRACT

The plastic bead method of Golding was evaluated as a rapid test for solids-not-fat in the milk of individual cows. Ten plastic beads each varying 1 mg. in density in the range of 1.025 to 1.034 are placed in a 4-oz. sample jar fitted with a plastic grid and a metal screw-cap. Milk is sampled directly into the sample jar and after the fat has been liquefied by heating to 104° F. and holding for 5 min., the test is made by counting the number of sinking beads at 68° F. A formula for converting the number of sinking beads to per cent SNF was calculated, using 1,873 milk samples from Guernsey, Holstein, and Jersey cows of 53 herds. This formula is: per cent SNF = 9.13 – 0.279 B + 0.307% F where B is the number of plastic beads sinking at 68° F. and per cent F is the percentage fat in the milk. In a second experiment, plastic beads and the lactometer of Watson were compared, using gravimetric assays for reference. On 300 milk samples from six breeds the standard deviation from regression was 0.17% SNF for the lactometer and 0.18% SNF for the plastic beads. The plastic bead method is sufficiently accurate for the routine testing of milk of individual cows for per cent SNF. The method is simple and rapid and requires no more milk than is routinely sampled for DHIA testing.


FOOTNOTES

1 Scientific Paper No. 1919, Washington Agricultural Experiment Station, Pullman. Project 1296.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1960 by the American Dairy Science Association ®.