JDS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Journal of Dairy Science Vol. 43 No. 1 28-41
© 1960 by American Dairy Science Association ®
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaufmann, O. W.
Right arrow Articles by Keppeler, R. A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kaufmann, O. W.
Right arrow Articles by Keppeler, R. A.

Relative Cleanability of Various Stainless Steel Finishes after Soiling with Inoculated Milk Solids1

O. W. Kaufmann, T. I. Hedrick, I. J. Pflug, C. G. Pheil and R. A. Keppeler

Departments of Microbiology and Public Health, of Dairy and of Agricultural Engineering, Michigan State University, East Lansing

ABSTRACT

A semiautomatic spray-washing device, which provided controlled rinsing and washing without brushing, was used to determine the relative cleanability of Type 302 stainless steel panels having a No. 2B, 3, 4, and 7 finish after soiling with skimmilk inoculated with Bacillus globigii spores.

Using the Direct Surface Agar Plate test at the 1 and 5% level, no significant difference was observed among these finishes after the test areas were rinsed (T-2), rinsed and washed with alkaline detergent (T-3), and rinsed, washed, and sanitized (T-4). This study indicates that the less highly polished finishes can be cleaned bacteriologically to the same degree as the highly polished No. 7 surface when the same cleaning cycle is used.

No significant difference in bacterial cleanability was observed among finishes at the 5% level with the Standard Swab Contact Test after T-3 and after T-4.

With the Direct Agar Contact Plate, a significant difference was observed among No. 2B, 3, 4, and 7 finishes after T-2, T-3, and T-4. The recovery of bacterial cells by this test was less than that obtained in the DSAP and Swab Contact Tests and indicates the unreliability of this test.

In all trials, the bacteria counts decreased markedly as the washing procedure was changed from a minimum rinse to a complete cycle of rinse-wash and sanitize.


FOOTNOTES

1 Contribution of the Michigan Agricultural Experiment Station, No. 2482. Aided in part by the American Iron and Steel Institute and the National Association of Dairy Equipment Manufacturers.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1960 by the American Dairy Science Association ®.